About Double Pigtail Ureteral Stent
|
Type
|
1) BIOFLEX D.J. STENT 2) BLACK SILICON D.J. STENT
|
|
Type Of Surgery
|
UROLOGY SURGERY
|
|
Usage/Application
|
Applied for internal drainage from the ureteropelvic junction to the bladder, as a provisional measu
|
Reliable Ureteral Drainage SolutionThis stent provides effective short- or long-term internal drainage of urine, maintaining ureteral patency and preventing obstruction. Its polished, smooth surface helps minimize patient discomfort and potential complications, making it suitable for a variety of clinical scenarios.
Multiple Features for Enhanced SafetyEquipped with radiopaque elements for clear visualization, soft pigtail ends, multiple side holes, and position markings, it allows for straightforward placement and monitoring. Its disposable nature contributes to infection control and overall patient safety in the urological setting.
Compliance and Quality AssuranceThe device is manufactured in accordance with ISO 13485 and CE standards, ensuring reliability, biocompatibility, and traceability. Sterilized using EO gas and packaged individually, the stent offers peace of mind to healthcare providers and patients alike.
FAQ's of Double Pigtail Ureteral Stent:
Q: How is the Double Pigtail Ureteral Stent inserted into the patient?
A: The stent is inserted using a cystoscope, a specialized instrument for visualizing and accessing the urinary tract. A guidewire may also be used to facilitate proper placement of the stent in the ureter.
Q: What are the available color options and dimensions for this stent?
A: Depending on the manufacturer, the stent is available in blue or transparent. Standard diameters range from 3 Fr to 8 Fr, and lengths vary from 22 to 30 cm to suit different anatomical needs.
Q: When should this stent be used and what is its primary benefit?
A: It is indicated for short or long-term management when internal drainage of urine from the kidney to the bladder is required, such as in cases of obstruction or post-surgical intervention. Its design ensures maintained ureteral patency and efficient urine flow.
Q: Is the Double Pigtail Ureteral Stent MRI compatible?
A: Most stents are MRI safe, though it is recommended to confirm with the specific manufacturer prior to MRI procedures to ensure compatibility.
Q: What is the removal process for the stent?
A: Removal is typically performed via cystoscopy or by using stent removal forceps, usually in a clinical setting by a trained healthcare professional.
Q: How is the stent sterilized and packaged?
A: The stent is sterilized using Ethylene Oxide (EO) gas and packaged individually in a sterile blister pack, ensuring it is ready for safe clinical use.
Q: What makes this stent suitable for urological procedures?
A: Features such as soft flexible ends, pigtail curled tips, radiopaque markings, multiple side holes for drainage, and smooth surface finish make it highly suitable and effective for urological applications.